Jerry Lang Combustion Consulting
Combustion & Emission Consultant
P.O. Box 865
Lindale, Texas 75771

(903) 882-5124
(903) 882-5308 Fax

 

 

Emissions control technology specifically targeting NOx reduction has evolved rapidly, such that combustion-side emission levels have been achieved which were historically thought impractical if not impossible – all without large capital investment or operating cost increase. In many cases, proven technology is being applied to existing equipment with the use of custom designed kits, and some technology is applied externally with very little other modifications.

Jerry Lang and his associates have developed emissions reduction technology over the past 20 years and hold 12 apparatus patents. Our approach is not dictated by a narrow range of brand name products, or hampered by an inflexible methodology. We have modified all types of combustion equipment and have worked extensively with various SCR & other exhaust treatment vendors. Our policy has always been to recommend the best-suited equipment for site-specific needs and operations.

We can offer you a unique service that will save you considerable time and capital investment.  Solutions will be proposed that are tailored to your site-specific conditions, and we will work with you from the initial concept phase, through procurement, installation, and start up.

We have worked either as a direct supplier of emission control equipment, or as a consultant on many projects for several major companies including ChevronTexaco, Chevron Phillips, ARCO, Shell, Kraft, Exxon, and Mobil.  Recent examples:

LOCATION

EQUIPMENT

RESULTS

ChevronTexaco, Richmond, CA

150,000-200,000#/hr boilers

NOx reduced ~95%, 7ppm.

Chevron Phillips, Baytown, TX

450,000#/hr boilers

NOx as low as 12ppm.

Chevron Phillips, Baytown, TX

100,000#/hr boilers

NOX ~ 20 ppm.

Global Octanes, Deer Park, TX

100,000#/hr package boiler

NOx ~18-20ppm

Chevron Phillips, St. James, LA

300,000#/hr boiler

NOx reduced ~87%.

Dow Chemical, Freeport, TX

500,000#/hr boiler

NOx reduced ~85%.

Genentech, Vacaville, CA

700 HP fire-tube boiler

NOx reduced ~86%

Natco Equilon Pipeline, CA

Crude oil heater

NOx reduced ~80%

Phillips 66, Sweeny, TX

Process Heater

NOx reduced ~75%

Ponderay Newsprint, Usk, WA

180,000 #/hr boiler

NOx <30ppm (propane)

TXU Electric, Frisco, TX

140MW corner-fired boiler

NOx reduced ~88%

Wyoming Refining Company, WY

18 MMBTU Naptha Heater

NOx reduced ~85%

We would appreciate an opportunity to assist you in your emission reduction program.  Please contact us at the above numbers, or send us an email.

Jerry Lang                  Sole Proprietor                      jerry@knocksout.com

Dave Scott                 Applications Design             dave@knocksout.com

Bill Morrow                 Drafting & Fabrication          bill@knocksout.com